We have recovered and re-reduced the raw M41 calibration images from December 2011. This revisits the original M41 calibration with plate solutions, frame-level pedigree and an explicit test of the filter labels. It also compares M41 with the revised NGC 6633 result.
The recovered sample
The two recovered nights contain 237 science exposures. Eighty-four have enough peak signal to be plausible stellar frames. Astrometry and Johnson UBV catalogue photometry leave 52 secure images:
| Recorded band | Secure images |
|---|---|
| B | 5 |
| V | 15 |
| VE1 | 13 |
| VE2 | 19 |
| IRCUT | 0 |
The 52 stellar colour loci form four separated groups. Every secure exposure agrees with its recorded B, V, VE1 or VE2 label, so none requires reassignment. We still have no usable IRCUT image. VE1 and IRCUT have similar passbands, and the M41 observations cannot distinguish them independently. The data therefore verify four observed photometric states; they do not supply independent wheel-position telemetry.
The losses are substantial. Of the 237 science exposures, 153 are too weak even under a permissive signal threshold. A further 28 plausible frames do not plate-solve, and four solved B images contain too few selected photoelectric standards. Filter-wheel, shutter, pointing, focus and transparency failures can all produce weak frames, so these 185 losses cannot be assigned uniquely to the wheel.
New small-aperture transformations
The calibration uses the Johnson UBV photoelectric measurements of Feinstein, Claria and Cabrera (1978), preserved in VizieR catalogue II/122B. We subtract a nightly median bias, measure stars in a 3-pixel aperture with a local sky annulus, and retain each raw file’s checksum. Instrumental magnitude is minst = −2.5 log10(ADU s−1), and the extinction-corrected magnitude is m0 = minst − kX. The catalogue transformations are:
M41
B = b0 + 15.669 + 0.288(B−V)
V = v0 + 15.201 − 0.039(B−V)
V = ve10 + 16.494 + 0.191(B−V)
V = ve20 + 14.083 + 1.066(B−V)
The median stellar residual scatter is 0.052, 0.037, 0.054 and 0.107 mag for B, V, VE1 and VE2, respectively. The B measurements span only X = 1.372–1.440, so their extrapolated zero-airmass zero point is provisional; the B colour coefficient is much better constrained.
For comparison, the corrected NGC 6633 equations from dark-corrected images without flat fields are:
NGC 6633
B = b0 + 15.038 + 0.152(B−V)
V = v0 + 15.233 − 0.063(B−V)
V = ve10 + 16.661 + 0.112(B−V)
V = ve20 + 14.309 + 1.082(B−V)
V = ircut0 + 16.526 + 0.137(B−V)
The original M41 values were B = 14.46 + B0 + 0.26(B−V), V = 15.15 + V0 − 0.08(B−V), and VE1 = 16.34 + VE10 + 0.06(B−V). Evaluating the new fits at the median observed airmasses gives zero points of 14.468, 15.087 and 16.337. These differ from the original values by +0.008, −0.063 and −0.003 mag. The corresponding colour-coefficient changes are +0.028, +0.041 and +0.131. The original B calibration and the three zero points at the observed airmass are therefore reproduced; the VE1 colour dependence is larger.
The old VE2 result was fitted to Cousins I. The new VE2 coefficient is relative to Johnson V, so a direct subtraction would mix two different standard bands. The new value confirms the strong red response of VE2.
Comparison with NGC 6633
The corrected NGC 6633 colour coefficients are +0.152 in B, −0.063 in V, +0.112 in VE1 and +1.082 in VE2 relative to V. M41 differs by +0.136, +0.025, +0.079 and −0.016, respectively. V and VE2 transfer closely. B and VE1 show cluster-dependent differences larger than their internal frame-to-frame scatter.
Zero points from the two clusters use different apertures and epochs, so their difference includes encircled energy, throughput and atmospheric terms. The NGC 6633 filter reassignment left B and V unchanged and moved VE1 and IRCUT by less than 0.007 mag. The B and VE1 differences between the clusters therefore do not arise from those two wheel failures.
What changes
The recovered M41 data do not reveal a mislabeled secure B, V, VE1 or VE2 frame. The 2011 small-aperture B calibration remains sound, and its V and VE1 zero points are reproduced. The main revisions are a larger VE1 colour term, explicit recognition that M41 supplies no IRCUT calibration, and a clear separation between the old VE2-to-I comparison and the new VE2-to-V relation.
The remaining checks are a matched reduction with the recovered superflats and a dark-current model, plus an external constraint capable of separating VE1 from IRCUT.